  • Gives a warning light when it starts to work, you can adjust it at any time
  • 16-bit microprocessor controlled and equipped with state-of-the-art digital hardware.
  • Electronic circuit with SMD technology.
  • Installation is done by the retrofit method.
  • The controller uses an industrial microcomputer control system, stable performance, simple operation.
  • Using the K-type thermocouple temperature probe, with easy installation, high temperature, long life, and other advantages.
  • 2-year warranty

Product Description

  • Input voltage: DC 12V
  • Motherboard Power: <3W
  • Temperature Controller Board Temperature range: -30 ~ 999℃
  • Measuring input: K-type thermocouple
  • Temperature measurement accuracy: ± 1 ℃
  • Analog output: 0-5V (For ECU’s, data loggers and etc.)
  • Output Type: one relay output
  • Display window: 38 * 20mm
  • Size: 79 * 51 * 27mm

Download EGT Controller Pdf

In stock (can be backordered)

Description
Reviews (0)

Included:

  • EGT K TYPE Thermocouple Amplifier Controller & Gauge & Analog Output
  • Optional EGT Sensor/ K Thermocouple Probe
  • 1 meter/3.3 ft cable
  • Instruction Manuel

Settings:
Power emperor window shows the current real-time temperature
Ent: Enter, according to a determined set value, press switch can be realized.
SET: Setting key, press once to enter the main menu (F1-F5)
“+” Plus key: increase the value display panel
“-” Minus key: decrease the value of the panel display

Internal Setting Description:
Press the SET panel display F1-F5, can be set for each parameter by key operation
F1: Set the desired temperature
F2: Setting the operating mode H = Heating, C = [refrigeration] This step is very important.
F3: Hysteresis setting, which is the number of degrees down to work again.
F4: Temperature correction, real-time display value = value + correction
F5: High-temperature alarm, reaches this temperature the thermostat will prompt alarm

Instructions
Set the target temperature value F1 (stop temperature)
Setting the F2 pattern, H is heating, C is Cooling
Setting back the difference, (the number of stop-start to fall again)

Display:
LLL / HHH: Sensor fault or sensor not connected
Mode / Cooling: lights shows that the current mode is a cooling mode
Mode/heating: Lit describes the current mode is a heating mode
Start: Lit explained that it had started the output relay is closed

Note: Relay output interface is a switch when it working, these two ports are connected. If not work, these two ports are not connected.